| Specifications of SINE WAVE UPS 600/800/1400VA | ||
| Input | Regulated UPS mode | |
| Under Voltage | 180 +/- 5 V | |
| Undervoltage Restoration | 185 +/- 5 V | |
| Over Voltage | 260 +/- 5 V | |
| Over Voltage Restoration | 255 +/- 5 V | |
| Unregulated UPS mode | ||
| Under Voltage | 100 +/- 10 V | |
| Undervoltage Restoration | 115 +/- 10 V | |
| Over Voltage | 285 +/- 10 V | |
| Over Voltage Restoration | 270 +/- 10Vss | |
| Output | ||
| Voltage (UPS Mode) | 230 V(Nominal) | |
| Voltage (Mains Mode) | Same as Input | |
| Frequency (UPS Mode) | 50Hz.±2% | |
| Frequency (Mains Mode) | Same as Input (45-55 Hz.) | |
| Overload | > 110 ‰ | |
| Transfer Time (typical a.s) | 10ms. | |
| Battery | Type | 12V/120AH-150AH Lead Acid Type |
| Number | 1 | |
| Typical Recharge Time | 10-12 Hrs. | |
| Protection | Battery Deep Discharge, Reverse Polarity, DC Overvoltage | |
| LED DISPLAY | ||
| UPS ON | Red | |
| SWITCH ON | White | |
| Low Battery Pre-Alarm | UPS ON+LOW BATTERY LED BLINKS | |
| Battery Low | Red | |
| Mains On | Red | |
| Smart Charge | Red (Along with Mains On LED) | |
| Overload | Red | |
| Short Circuit | OVERLOAD RED LED BLINKING | |
| No Load Shut Down | Red | |
| Battery Charged | Mains On LED steady | |
| Charging Fuse Blown | Mains On + Smart Charge blinking | |
| ALARMS | Low Battery Pre-Alarm | Beeps every 1.5 Minutes |
| Low Battery Trip | Beeps Continuously for 10 seconds | |
| Overload | Beeps Continuously for 10 seconds | |
| Mains to UPS | Beeps every 2 seconds for 5 times | |
| Short Circuit | Beeps Continuously for 10 seconds | |
| No Load Shut Down | Beeps Continuously for 10 seconds | |
| MCB Trip | Beeps every 12 minutes | |
| ENVIRONMENTAL | Operating Temperature | 0-45o C (32-113 o F) |
| Storage Temperature | 0-45o C (32-113 o F) | |
| Humidity | 0-95 % RH non -condensing | |
| *Due to Continuous Product improvements,specs are subject to change without notice. | ||
| Specifications of SINEWAVE UPS 1500VA | ||
| Input | Regulated UPS mode | |
| Under Voltage | 180 +/- 5 V | |
| Undervoltage Restoration | 185 +/- 5 V | |
| Over Voltage | 260 +/- 5 V | |
| Over Voltage Restoration | 255 +/- 5 V | |
| Unregulated UPS mode | ||
| Under Voltage | 100 +/- 10 V | |
| Undervoltage Restoration | 115 +/- 10 V | |
| Over Voltage | 285 +/- 10 V | |
| Over Voltage Restoration | 270 +/- 10Vss | |
| Output | ||
| Voltage (UPS Mode) | 230 V(Nominal) | |
| Voltage (Mains Mode) | Same as Input | |
| Frequency (UPS Mode) | 50Hz.±2% | |
| Frequency (Mains Mode) | Same as Input (45-55 Hz.) | |
| Overload | > 110 ‰ | |
| Transfer Time (typical a.s) | 10ms. | |
| Battery | Type | 12V/120AH-150AH Lead Acid Type |
| Number | 1 | |
| Typical Recharge Time | 10-12 Hrs. | |
| Protection | Battery Deep Discharge, Reverse Polarity, DC Overvoltage | |
| DISPLAY | ||
| UPS ON | ON | |
| Low Battery Pre-Alarm | Lo | |
| Battery Low | Lo | |
| Mains On | AC | |
| Smart Charge | CH | |
| Overload | OL (Steady) | |
| Short Circuit | OL (Blinking) | |
| No Load Shut Down | Red | |
| Battery Charged | 99‰ | |
| Over Temperautre | th | |
| MCB Trip | bt | |
| ALARMS | Low Battery Pre-Alarm | Beeps every 10Seconds |
| Low Battery Trip | Beeps Continuously for 10 seconds | |
| Overload | Beeps Continuously for 10 seconds | |
| Mains to UPS | Beeps every 2 seconds for 5 times | |
| Short Circuit | Beeps Continuously for 10 seconds | |
| No Load Shut Down | Beeps Continuously for 10 seconds | |
| MCB Trip | Beeps every 12 minutes | |
| ENVIRONMENTAL | ||
| Operating Temperature | 0-45o C (32-113 o F) | |
| Storage Temperature | 0-45o C (32-113 o F) | |
| Humidity | 0-95 % RH non - condensing | |
| *Due to Continuous Product improvements,specs are subject to change without notice. | ||